AXO SERIES AUTOMATION FOR SWING GATES INSTALLATION MANUAL AX3024 / AX5024 English EN
EN ENGLISH ENGLISH WARNING! Important instructions for the safety of people: READ CAREFULLY! Foreword • Use of the products must be restricted to its intended use (i.e. that for which it was expressly built for). Any other use is to be considered dangerous. Came Cancelli Automatici S.p.A. is not liable for any damage resulting from improper, wrongful or unreasonable use • Keep these warnings with the installation and use manuals issued with the automated system.
1. GENERAL POINTS These general conditions shall apply to all purchase agreements for Came Cancelli Automatici SpA materials, hereinafter called “the company”. 2. OFFERS AND QUOTATIONS The company’s quotations are valid for a 30-day period at the most starting from the date they are sent. 3. ORDERS The sale agreement is executed once the written order is confirmed by Came Cancelli Automatici Spa or when the order is fulfilled by the company.
“IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS” “CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY” “THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS” 1 Legend of symbols This symbol tells you that the sections concern safety issues. This symbol tells you what to say to the end-users. 2 Intended use and application 2.1 Intended use The AXO operator is designed to automate swing gates used in residential or condominium settings..
GEARMOTOR AX402306 / AX412306 Control board power supply: 230V A.C. 50/60Hz Motor power supply: 230V A.C. 50/60Hz Max draw.: 1,5A Power: 175W Adjustable thrust: 500÷4500N Opening time(90°): 28s Duty cycle: 30% Protection rating: IP44 Motor’s thermal protection: 150 C° # GEARMOTOR AX71230 Control board power supply: 230V A.C. 50/60Hz Motor power supply: 230V A.C. 50/60Hz Max draw.
5 Installation Installation must be carried out by expert qualified personnel and in full compliance with current regulations. 5.
1) AXO operator 2) Control panel 3) Reception antenna 4) Flashing light 5) Selector switch 6) Photocells 7) Electric cable junction box 8) Mechanical gate stops 9) Photocell column 6 ENGLISH Pag. 5 - Manual code: 119DU85 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. 5.
Pillar bracket Gate bracket E E AX302304 - AX402306 - AX412306 AX71230 Gate leaves of up to 4m Opening angle A mm B mm C max mm E mm 90° 130 130 70 800 120° 150 80 0 800 120° 140 100 50 800 Gate leaves of up to 7 m Opening angle A mm B mm C max mm E mm 90° 200 220 150 1100 120° 220 220 100 1100 Assemble and weld the two parts of the pillar bracket.
ENGLISH Pag. 7 - Manual code: 119DU85 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. Weld the gate bracket to the gate leaf making sure the quotas shown in the table are met. Note: for AX5024 gearmotors, require an additional 10 mm shim between the gate and the bracket.
Gate bracket UNI6593 Ø8 washer Screw UNI5739 M8x10 Release the gearmotor (see paragraph on manual release), completely open the gate leaf, loosen the nuts of the opening mechanical stop and position it up against the attachment pin, then secure it. Opening mechanical stop Attachment pin Close the gate leaf, loosen the nuts on the closing mechanical stop, place it up against the attachment pin, then secure it. Attachment pin Closing mechanical stop Pag. 8 - Manual code: 119DU85 ver. 0.
5.6 Manual release of the gearmotor ENGLISH 5.7 Connecting to the control panel For the electrical connection procedures, use the junction box and branching boxes. ZM3E Control panel Encoder B , Encoder A Power 230V a.c. - 50/60 Hz white brown green brown black blue Connecting the 230V a.c. delayed opening gearmotor white brown green brown black blue yellow/green Connecting the 230V a.c. delayed closing gearmotor yellow/green Pag. 9 - Manual code: 119DU85 ver. 0.
(non-issued) Supplementary bracket A A TABLE 1 TABLE 2 Opening A (mm) B (mm) E (mm) Opening A (mm) B (mm) E (mm) 90° 130 130 800 90° 200 220 1100 Weld pillar bracket to the non-issued supplementary bracket, while gate is open, then secure the brackets to the pillar, making sure the “A” and “B” quotas shown in table 1 are met. Weld, or secure with proper screws, the gate bracket, making sure the “E” quota is met, as shown in table 1.
ENGLISH Pag. 11 - Manual code: 119DU85 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. Fully close the gate-leaf, place the mechanical stop against it with the pin attachment and fix it in place.
6 Safety instructions This product must only be employed for its originally intended use. The automation installation using these gearmotors requires adequate safety systems on the gate leaves to detect any obstacles (e.g. sensitive edges), in compliance with EN12445 and EN12453 Technical Standards relative to the impact force generated by the moving gate. Any other use is wrong and potentially dangerous.
7 Maintenance Periodic maintenance to be carried out by the end-user is as follows: wipe clean the glass surface of the photocells; check that the safety devices work properly; remove any obstructions. We suggest checking the state of lubrication and tightness of the anchoring screws on the operator. To check the efficiency of the safety devices, move an object in front of the photocells when gate is closing. If the operator inverts the motion or stops, the photocells are working properly.
Periodic maintenance log for end-user (every 6 moths). Signature 7.3 Extra-ordinary maintenance The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised firms. N.B.: Any extraordinary maintenance must be performed by specialised technicians.
Installer’s stamp Operator name Date of job Technician’s signature Job performed _______________________________________________________________________________________ __________________________________________________________________________________________________ ____________________________________________________________________________________________ Installer’s stamp Operator name Date of job Technician’s signature Requester’s signature Job performed ____________________________________________