< CY Input >
Disabled
CY Input
< Disabled >
CY Input
< C2 >
CY Input
< C3 >
CY Input
< C4 >
CY Input
< C1 >
CY Input
< C7 >
CY Input
< C8 >
CX input: the N.C. safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when
opening), C3 (partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for
sensitive edges) or, be deactivated. See safety devices on electrical connections.
< CX Input >
Disabled
CX Input
< Disabled >
CX Input
< C2 >
CX Input
< C3 >
CX Input
< C4 >
CX Input
< C1 >
Total Stop
< Turn on >
< Total Stop >
Turn o n
Total Stop
< Disabled >
Total Stop: this function stops the gate and consequently excludes any automatic closing cycle; for movement to resume, you need to
use the keypad or transmitter. Insert safety device on [1-2]; Insert the safety device on [1 -2]; if unused, select “Deactivated”
CX Input
< C7 >
CX Input
< C8 >
CY input: safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when opening), C3
(partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for sensitive edges)
or, be deactivated. See safety devices on electrical connections.
< LANGUAGE >
ANGUAG
English
E
FUNCTIONS
TIMING ADJ.
I
J
USERS
INFO
Imp. Run
n
< LANGUAGE >
ANGUAG
English
E
FUNCTIONS
TIMING ADJ.
I
J
USERS
INFO
Imp. Run
n
< LANGUAGE >
ANGUAG
English
E
FUNCTIONS
TIMING ADJ.
I
J
USERS
INFO
Imp. Run
n