Z SERIES CONTROL PANEL FOR 24V OPERATORS INSTALLATION MANUAL ZLJ24 English EN
“IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS” “CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY” “THIS MANUAL IS ONLY FOR PROFESSIONAL INSTALLERS OR QUALIFIED PERSONS” This symbol indicates sections to be read with particular care. This symbol indicates sections concerning safety. This symbol indicates notes to communicate to users. 2 Intended use and application 2.1 Intended use The ZLJ24 control panel is engineered to command 24V D.C.
4.1 Dimensions, spans and anchoring holes ENGLISH Pag. 3 - Manual code: 319U98 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. (mm) 4.
5 Installation Installation must be carried out by expert qualified personnel and in full observance of regulations in force. 5.2 Tools and materials Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with the current standards and regulations. The following figure illustrates the minimum equipment needed by the installer. Here are some examples. 5.
) Snap the cover into place onto the hinges. Close it and fix it using the provided screws. ENGLISH Pag. 5 - Manual code: 319U98 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. 6) After the adjustments and settings, fix the cover using the provided screws. 6 Electrical connections 6.
Signalling and Lighting devices Open gate indicator-light (socket rating: 24V - 3W max.). Turns on when the gate is ajar or open. It turns off when the gate is closed. Cycle lamp: (contact rating: 24V – 25W max.) It lights up the driving area and stays on from the moment the gate begins to open until it is fully closed (including the automatic closing time). If automatic closing is not activated, the lamp stays on only during movement. Command devices N.B.
Gearmotor, mechanical stops FERNI FROG-A24 Pag. 7 - Manual code: 319U98 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. M2 - 24V D.C. gearmotor featuring delayed action on closing FROG-A24 F4024 FERNI ENGLISH M1 - 24V D.C.
DF (DIR) # . # (DOC) &53)"),% M! 48 # .# 48 48 At each opening and closing command, the control board assesses the efficiency status of the control devices (photocells). Any anomaly found is signalled with the flashing of the LED on the control panel. Consequently it cancels any commands coming from the remote control or the button.
7 Programming Lingua Italiano Pag. 9 - Manual code: 319U98 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. Þ The ESC key is for: - exiting the menu; - cancelling modifications. ß { The < > keys are for: - shifting from one menu item to another; - increase or decrease values. { the <...
7.3 Menu structure < LANGUAGE > ENTER > > > > < FUNCTIONS > > > ENTER < Imp. Run > > < ENCODER > See detailed functions on pages 19, 20 and 21 (the “ENCODER” function, appears only if selected from the “Config.” function in the FUNCTIONS menu. ENTER > < TIMING ADJ > ENTER > < USERS < > T.C.A. < 0s. > ENTER > confirm? (no) ENTER > ENTER > > Choose User <001:-U001-> < Mod. name > < 300s.
< Turn on > ENTER > ENTER > > > > < M2 > ENTER > Frog ENTER > > > > AMICO FAST < Turn on > ENTER > > > > > > AXO
7.4 Main menu LANGUAGE English > < ENGLISH Press ENTER for 1 second FUNCTIONS > < ENCODER > It appears only if selected from the “Config.” Section in the FUNCTIONS menu. < TEST MOT. > < INFO > < < TIMING ADJ. > USERS 250 > Max. 250 users 7.5 Language menu Select language: selects among the languages displayed. LANGUAGE < English > < LANGUAGE > English LANGUAGE < Deutsch > LANGUAGE < Francais > FUNCTIONS Imp. Run n LANGUAGE < Italiano > TIMING IMING ADJ.
Obstacle detected: when motor is stopped (gate closed or after a total stop command) it prevents any movement if safety devices, such as photocells, detect any obstacles. < LANGUAGE ANGUAG > E English X2 Imp. Run n Obstacle Det. < Disabled > X2 Obstacle Det. < Turn on > Pag. 13 - Manual code: 319U98 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.
Total Stop: this function stops the gate and consequently excludes any automatic closing cycle; for movement to resume, you need to use the keypad or transmitter. Insert safety device on [1-2]; Insert the safety device on [1 -2]; if unused, select “Deactivated” < LANGUAGE ANGUAG > E English X6 < Total Stop > Turn on Imp. Run n < Total Stop Turn on > X2 Total Stop < Disabled > TIMING I ADJ. J USERS INFO CX input: the N.C.
CZ input: safety contact input can take on the following functions: C1 (re-opening when closing), C2 (re-closing when opening), C3 (partial stop), C4 (obstacle stall), C7 (re-opening when closing, for sensitive edges), C8 (re-closing when opening, for sensitive edges) or, be deactivated. See safety devices on electrical connections. X9 < LANGUAGE ANGUAG > E English < CZ Input > Disabled CZ Input < Disabled > < CZ Input C1 > CZ Input < C8 > < CZ Input C2 > CZ Input C7 > < CZ Input C3 > Pag.
Endstop: configure the endpoints are normally closed or open contacts. N.B.: this function appears only if selected from the “Config.” function in the FUNCTIONS menu. < LANGUAGE ANGUAG > E English X 13 < Imp. Run n endstop N.C > < endstop N.C > X2 TIMING I ADJ. J endstop N.A < > USERS Command 2-7: setting the 2-7 contact to step-by- step mode (open-close) or sequential (open-stop-close-stop). < LANGUAGE ANGUAG > E English X 14 < cmd 2-7 > Op.-Stop-Cl. FUNCTIONS Imp. Run n cmd 2-7
B1-B2 output: setting contact B1-B2 to MONO-STABLE or BI-STABLE (switch) mode. X 17 < LANGUAGE ANGUAG > E English < output B1-B2 Monostable FUNCTIONS > output B1-B2 < Monostable TIMING I ADJ. J < output B1-B2 Bistable > USERS 7.7 Gate-Run Setting Menu Number of motors: setting the number of motors, either one or two, depending on the number of gate leaves installed on the system. < LANGUAGE ANGUAG > E English li h FUNCTIONS < Imp. Run No. Motors M1 + M2 > < No.
% speed of deceleration: setting up the deceleration speed, expressed as a percentage between 50% and 100%. < LANGUAGE ANGUAG > E English li h X3 < low Down Spd > 20 Imp. Run TIMING I ADJ. J low Down Spd < 20 > X2 low Down Spd < 21 > USERS Delayed start: After an open or close command, the gate leaves start at a slow speed for a few seconds. < LANGUAGE ANGUAG > E English li h X4 < Slow Star > Disabled FUNCTIONS Partenza Rall. < Disabled > Imp. Run X2 TIMING I ADJ. J Partenza Rall.
Deceleration time: gate leaf deceleration time before each endpoint. The time can be set anywhere between 0” to 30”. N.B.: this function only appears if the decelerations and Fcap-RallCh. are selected. < LANGUAGE ANGUAG > E English li h Pag. 19 - Manual code: 319U98 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. TIMING I ADJ.
Encoder Deceleration: this activates the opening and closing deceleration starting points. F FUNCTIONS X3 Imp. Run n < Slow run Enc > ON TIMING ADJ. T D Slow run Enc ON > X2 USERS < Slow run Enc OFF > INFO M1 opening deceleration%: this adjusts the (M1) first motor’s deceleration starting point before the opening endpoint. The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 28. N.B.
M2 closing deceleration %: this adjusts the (M2) second motor’s deceleration starting point before the closing endpoint. The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 28. N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu. F FUNCTIONS < Pag. 21 - Manual code: 319U98 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a.
7.8 Time setting menu Automatic closing: to set the waiting time when gate is in the open position. Once this time is elapsed, the gate closes automatically. The waiting time can be set to between 0” and 300”. ENCODER R < TIMING ADJ. USERS A.C.T. 10s. > < A.C.T. 10s. > X2 INFO < A.C.T. 11s. > Automatic Pedestrian Closing: waiting time of the (M2) second gate leaf when in the open position. Once this time interval has elapsed, the gate automatically closes.
M2 delayed closing: the waiting time of the (M2) second gate leaf, unlike the (M1) first one, after each closing command. the waiting time can be set to between 0” and 60”. Imp. Run n < Pag. 23 - Manual code: 319U98 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. TIMING ADJ. USERS Cl. Delay M2 2s > < Cl.
Slow down time: the gate leaf’s deceleration time before every endpoint. The time can be set to between 0” and 30”. N.B.: this function only appears if the decelerations are selected. Imp. Run n X8 ENCODER R < Slow down time > 5s. USERS X2 Slow down time < 6s. > INFO 7.9 Users Radio Menu Add User: to create a new user and assigned function (max. 250 users). Add User < Add User > FUNCTIONS F S Imp.
Related Function: to change the function assigned to the user. X3 < Related Func > FUNCTIONS F S < Choose User 001:--001-- > Imp. Run n X2 Pag. 25 - Manual code: 319U98 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. USERS < Choose User 002:--002-- INFO > See detailed description on page 27 TEST MOT.
Restore backup: to load the data saved on the memory roll onto card. X7 Restore backup ENGLISH Imp. Run n ENCODER R X2 Restore backup USERS INFO Restore backup READ:250 TEST MOT. 7.10 nfo Menu Version: to view software version. Number of gate runs: to view the number of runs performed by the gate. Starting Mssg: to view the starting message, confirm with ENTER to change text.
7.12 Decoding card Connect the required (R700, AF43S cards) to insert, change, remove and command the operator via transmitter, card or transponder. Insert the memory roll to save and load all setting including users registered by another card. R700 Card ENGLISH Pag. 27 - Manual code: 319U98 ver. 0.1 01/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a.
1) From the Users menu, select “Add User”. Press ENTER to confirm. 3) Choose which function to assign to the user.... Þ Add User ß Related Func. Þ 2-7 ß 2) Select “ confirm (yes)” and press ENTER key to confirm. Add User Þ confirm? (yes) ß 4) .... will ask to input a code. Send the code with the radiocommand button or slide-through card or transponder. Waiting Code >>>> ACCESS CONTROL 5) ... once the code is inputted, the user name will come up showing the type of command that was memorised..
7.15 Changing code Mod. Code Choose User 3) .... you will be asked to input a code. Send the code using the transmitter button or the slide through card or the transponder. Waiting Code 4) .. once the code is inputted, the user name will come up showing the type of command that was memorised... >>>> ENGLISH 2) Choose the user Þ 001:--U001-- ß name for which you Choose User wish to change the Þ 002:--U002-- ß code and press ENTER to confirm. --002-radio ACCESS CONTROL Pag.
7.17 Gate run calibration 1) From the Encoder menu, select “Set Encoder”. Press ENTER to confirm. 2) Select “confirm (yes) and press ENTER to confirm. 3) the gate leaf of the first motor will perform a closing run until fully closed..... 0 0 5) …then, the gate leaf of the second motor, will perform and opening run until fully open… 0 0 4) …then, the gate leaf of the second motor will perform the same manoeuvre… 6) ...
7.19 Illustration depicting the areas and points of deceleration and final opening and closing approaches per encoder device.
English - Manual code: ........... ver. ... ../.... © CAME cancelli automatici s.p.a. The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users. CAME France S.a. 7, Rue Des Haras Z.i.