Installation Instructions

CX-PS13 V3 Installation Instructions
www.camdencontrols.com
Toll Free: 1.877.226.3369
5502 Timberlea Blvd.,
Mississauga, ON Canada L4W 2T7
Revised: July 2012
Part No.: 40-82B104
IMPORTANT
Input transformer required.
DO NOT connect circuit to
the 120 VAC line.
Gell Cell
Battery
Output
To Load
Input
From Transformer
Wiring Diagram
Transformer Selection
Required
Output
Voltage
Transformer
Volts
VA
6 VDC
6 9 VAC
20
9 VDC
9 12 VAC
20
12 VDC
12 14 VAC
30
13.8 VDC
14 16 VAC
30
18 VDC
18 20 VAC
30
24 VDC
24 26 VAC
40
Voltage Selection
Jumpers
Voltage
Adjustment