Spec Sheet
CX-EMF-2 MULTI-FUNCTION RELAY
APPLICATION 3 - SINGLE DOOR, NORMALLY SECURED RESTROOM DOOR
This application is a shared-use single (normally
locked) restroom door in facilities such as doctors
offices, hospitals, shopping malls, etc. The relay
provides control of the lock, operator, and switches,
to provide the utmost in facility security, safety for
the occupants, yet still be easy to install and program.
In this application the door is normally locked
whether occupied or not. It may be unlocked by key-
switch, keypad, or another credential. The EMF-2
can be configured to activate the door operator
immediately, or after pressing the wall-switch within
the (adjustable) time period. Once the door has
closed, pressing the ”Push to Lock” button removes
the exterior keypad / key-switch from the circuit. The
electric lock will pulse twice to let the user know
that the door is secure, and an output is available to
light an Occupied LED (s).
To exit the restroom, simply push the interior wall
switch. The door unlocks, opens and resets the
system. Should the door be opened manually, the
magnet switch will reset the system. Unique to the
EMF-2 is the emergency input, which allows a panic button to unlock, open the door (optional), and send an
emergency signal for assistance. The output can be maintained or pulsed.
As an added safety feature, the EMF-2 can be set to automatically reset (and unlock) after 15 minutes time.
APPLICATION 4 – 2 DOOR SHARED-USE RESTROOM
This application is a shared-use (normally unlocked)
restroom between two suites (and therefore utilizing
two doors), in facilities such as nursing homes &
hospitals, etc. The relay provides control of both
locks, operators, and all switches, to provide the
utmost in flexibility, safety for the occupants, yet still
be easy to install and program.
Either door is opened automatically by pressing the
respective exterior wall switch. Once the door has
closed, pressing either ”Push to Lock” button inside
then locks both doors – the strike is energized, and
exterior switches are removed from the circuit. To
exit the restroom, simply push either interior wall
switch. The respective door unlocks, opens and resets
the system. Should either door be opened manually,
the magnet switch will reset the system.
Unique to the EMF-2 is the emergency input, which
allows a panic button to unlock, open (one or both)
door(s), (optional), and send an emergency signal for
assistance. The output can be maintained or pulsed.
As an added safety feature, the EMF-2 can be set to
automatically reset (and unlock) after 15 minutes time.
It is strongly encouraged to utilize the dry contact
output (Relay #5) or the LED output to indicate
”Occupied” on the exterior of both doors to let
others know the restroom is in use.
PUSH
TO
LOCK
Restroom
Door Contro l
Relay
PO WER
PU S H
INTERIOR SWITCH
LOCK SWITCH
PA NIC
SWITCH
(OPTIONA L )
DO O R C ONTA CTS
EXTER I OR SW ITCH
DOOR
OPER ATOR
ELECTRI C
LOCK
(IF EQUIPPED )
12/24 V AC/ DC
POWER
PU S H
ASSIS TANC E
REQU I RED
! !
OCCUP I ED
1
2
3
4 5 6
7 8 9
*
0 #
KEYPAD
PUSH
TO
LOCK
2 - Door
Restroom Door
Interface
PO WER
PU S H
INTERIOR SWITCH
LOCK SWITCH
PA NIC
SWITCH
(OPTIONA L )
DO O R C ONTA CTS
EXTER I OR SW ITCH
12/24 V AC/ DC
POWER
PU S H
ASSIS TANC E
REQU I RED
! !
OCCUP I ED
DOOR
OPER ATOR
ELECTRI C
LOCK
(IF EQUIPPED )
ELECTRI C
LOCK
(IF EQUIPPED )
PUSH
TO
INTERIOR SWITCH
LOCK SWITCH
DO O R C ONTA CTS
EXTER I OR SW ITCH
PU S H
OCCUP I ED
DOOR
OPER ATOR
LOCK
PU S H
DOOR A