User's Manual
Table Of Contents
- 1 Overview
- 2 Installation, wiring and debugging
- 3 Getting Started
- 4.Basic Functions
- 4.1 Management menu operations
- 4.1.1 Change Admin Password
- 4.1.2 Set or delete Super-open-password
- 4.1.3 Set admin card
- 4.1.4 Delete admin card
- 4.1.5 Set Machine Mode
- 4.1.6 Limits types of reading card
- 4.1.7 Restore to default settings
- 4.1.8 Add User
- 4.1.9 Delete user
- 4.1.10 Set open door methods
- 4.1.11 Set Multi-card to open door
- 4.1.12 Set lock working mode
- 4.1.13 Set Limits User Mode
- 4.1.14 Set Open-time
- 4.1.15 Set notification to close door
- 4.1.16 Set Alarm-time
- 4.1.17 Set Anti-dismantle alarm function
- 4.1.18 Set alarm or doorbell output function
- 4.1.19 Set Anti-crack function
- 4.1.20 Set LED indicator light mode
- 4.1.21 Adjust the brightness of the normally brigh
- 4.1.22 Set key backlit mode
- 4.1.23 Adjust brightness of key backlit
- 4.1.24 Set buzzer mode
- 4.1.25 Adjust key volume
- 4.1.26 Set the # key whether it can be used doorbe
- 4.1.27 Set doorbell key mode
- 4.2.28Set reader output format
- 4.2 Admin card or PIN operation
- 4.3Users operation
- 4.4 Other operations
- 4.5 Operation characteristics in different machine
- 4.1 Management menu operations
- 5 Management menu summary table
- 6 Precautions in use
- 7 Common troubleshooting
- 6 -
2 Installation, wiring and debugging
2.1 Installation
With the special anti-demolition screw-driver remove the anti-demolition screw at the bottom of the device. Take off the
bottom case, and contrast the opening position of the bottom case and use the impact drilling to open the corresponding hole
on the wall. It includes an outlet hole with a diameter greater than 8mm and four plastic screw holes with a diameter of 6mm.
Then insert four matching plastic expansion screws, fix the bottom case on the wall with four matching self-tapping screws.
2.2 Wiring
According to the selected wiring diagram, cut the lead wire to the right length and cut off the excess thread, through the wall
or in the embedded box, connect the system line with the wiring diagram. Be careful not to connect the wrong or short circuit,
otherwise it may burn the machine. After checking, power on for a short time, test if the indicator light is normal and if the
buzzer ring one time beep. Otherwise, power off immediately and recheck the wiring properly. After check again and if all is
well, install the front case of the product onto the bottom case on the wall and fix it with the anti-demolition screw as below:
The product wiring colors and functions are shown in the following table:
Color
Symbol
Functions
Light green
AC2
One port of the AC power supply
Blue
NO
Normal open port of Relay
Purple
COM
Common port of Relay
Orange
NC
Normal close port of Relay
Grey
ALARM(BELL)
Alarm (or doorbell) signal MOS drain output
Yellow
OPEN(BEEP)
Exit button input(or external control input of buzzer)
Brown
D_IN(LED_G)
Door contact input (or external control input of green LED)