User's Manual
Table Of Contents
- 1 Overview
- 2 Installation, wiring and debugging
- 3 Getting Started
- 4.Basic Functions
- 4.1 Management menu operations
- 4.1.1 Change Admin Password
- 4.1.2 Set or delete Super-open-password
- 4.1.3 Set admin card
- 4.1.4 Delete admin card
- 4.1.5 Set Machine Mode
- 4.1.6 Limits types of reading card
- 4.1.7 Restore to default settings
- 4.1.8 Add User
- 4.1.9 Delete user
- 4.1.10 Set open door methods
- 4.1.11 Set Multi-card to open door
- 4.1.12 Set lock working mode
- 4.1.13 Set Limits User Mode
- 4.1.14 Set Open-time
- 4.1.15 Set notification to close door
- 4.1.16 Set Alarm-time
- 4.1.17 Set Anti-dismantle alarm function
- 4.1.18 Set alarm or doorbell output function
- 4.1.19 Set Anti-crack function
- 4.1.20 Set LED indicator light mode
- 4.1.21 Adjust the brightness of the normally brigh
- 4.1.22 Set key backlit mode
- 4.1.23 Adjust brightness of key backlit
- 4.1.24 Set buzzer mode
- 4.1.25 Adjust key volume
- 4.1.26 Set the # key whether it can be used doorbe
- 4.1.27 Set doorbell key mode
- 4.2.28Set reader output format
- 4.2 Admin card or PIN operation
- 4.3Users operation
- 4.4 Other operations
- 4.5 Operation characteristics in different machine
- 4.1 Management menu operations
- 5 Management menu summary table
- 6 Precautions in use
- 7 Common troubleshooting
- 34 -
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) #
Menu
Parameter or operation step
Function
Default value
2#
Double-doors mode
3#
Interlock mode
9#
Demo mode
09
0000#
Restore default settings, admin password and user
information unchanged.
32
0#
Set lock to Delay mode
0
1#
Set lock to Switch mode
2#
Set the lock to Normal-open mode
34
0#
Set Open-time to 50mS
2
(1-999)#
Set Open-time from 1 to 999S
51
1,1,…,#
Decrease the brightness of the normally bright red indicator
18
2,2,…,#
Increase the brightness of the normally bright red indicator
52
0#
Key backlit is always off
1
1#
Key backlit is always on
(2-99)#
After delay 2-99 seconds, Key backlit turn to micro light
53
1,1,…,#
Decrease the brightness of the backlit
14
2,2,…,#
Increase the brightness of the backlit
55
1,1,…,#
Decrease the keypad tone
10
2,2,…,#
Increase the keypad tone
6 Precautions in use
Lead line cannot be connected wrong, especially the power line, otherwise the machine may be burned or not work
properly.
Because the machine internal relay is used for signal output, cannot directly drive large power load, in order to ensure
the long-term stable operation of the machine, the electric lock be not connected directly with NO, NC, COM of the
machine, but driven by an access control special power supply.
When you enter the management mode or change the user PIN, you must press and hold the * key for more than two
seconds to be valid.
Is for the sake of safety, the default admin initial password 888888 only support the menu 00, which forced users to
change the 6-digit admin password, or cannot access other settings.
The factory default mode is the single-door mode. If you need other mode functions, you must enter the appropriate
mode to operate properly. In different modes, the management menu is also different.