User's Manual
Table Of Contents
- 1 Overview
- 2 Installation, wiring and debugging
- 3 Getting Started
- 4.Basic Functions
- 4.1 Management menu operations
- 4.1.1 Change Admin Password
- 4.1.2 Set or delete Super-open-password
- 4.1.3 Set admin card
- 4.1.4 Delete admin card
- 4.1.5 Set Machine Mode
- 4.1.6 Limits types of reading card
- 4.1.7 Restore to default settings
- 4.1.8 Add User
- 4.1.9 Delete user
- 4.1.10 Set open door methods
- 4.1.11 Set Multi-card to open door
- 4.1.12 Set lock working mode
- 4.1.13 Set Limits User Mode
- 4.1.14 Set Open-time
- 4.1.15 Set notification to close door
- 4.1.16 Set Alarm-time
- 4.1.17 Set Anti-dismantle alarm function
- 4.1.18 Set alarm or doorbell output function
- 4.1.19 Set Anti-crack function
- 4.1.20 Set LED indicator light mode
- 4.1.21 Adjust the brightness of the normally brigh
- 4.1.22 Set key backlit mode
- 4.1.23 Adjust brightness of key backlit
- 4.1.24 Set buzzer mode
- 4.1.25 Adjust key volume
- 4.1.26 Set the # key whether it can be used doorbe
- 4.1.27 Set doorbell key mode
- 4.2.28Set reader output format
- 4.2 Admin card or PIN operation
- 4.3Users operation
- 4.4 Other operations
- 4.5 Operation characteristics in different machine
- 4.1 Management menu operations
- 5 Management menu summary table
- 6 Precautions in use
- 7 Common troubleshooting
- 26 -
Exit operation:
Press exit button
Note: In addition to the exit operation, make sure that the machine is not in a disable user state. You must first set up good
way to open the door, open the door by multi-card also needs to set a good quantity of card. If card or PIN is valid, a long
“beep”, the lock will be opened. During the opening time, LED turns green. After that, LED turns red and keep. In card & PIN
open mode or multi-card open door mode, the interval time of reading card or inputting PIN cannot be more than 5 seconds.
4.4 Other operations
4.4.1 Cancel alarming
Read admin or the user card, or (Admin Password)#, or 2(Admin Password)#
Note: Add 2 in front of Admin Password, that is the 7 digits Admin Password of zone 2. When the alarm has happened, the
buzzer will ring "Wu, Wu" alarm sound. User can cancel the alarm with reading the valid user card and inputting Admin
Password. But the alarm output signal of the anti-duress card can’t be canceled.
4.4.2 Admin Password initialization
When you forget the Admin Password, you can restore it to the initial password by special operation. Operation as follows:
Power off, press the # keys do not move, and power on. Release the # key after two “beep”. Admin password has restored to
888888. But the other parameters, the info of the card and pin will be still kept.
4.4.3 Restore factory settings
When you forget the Admin Password, or when the user randomly confused various parameters, you can return to the normal
situation by restoring the factory settings, as follows:
Power off, press the * keys do not move, and power on. Release the * key after two “beep”. Admin Password has restored to
888888, while the machine parameters revert to factory settings, the specific default values are shown in the schedule, other
cards and PIN information will not be deleted.
4.5 Operation characteristics in different machine modes
4.5.1 Operation characteristics in reader mode
In the reader mode, you can only operate menus: 00-04, 09, 40-42, 50-57, 60-64. Among them, the 01 and 02 menus can
only be added and deleted Set-card.
Reading Set-card, the machine does not output wiegand signal, reading the other card or inputting user PIN, the machine
output wiegand signal.
The three control wires, LED_R, LED_G and BEEP, their functions are as follows:
LED_G: Green LED control wire, LED turns to green when low level.
LED_R: Red LED control wire, LED turns to red when low level.