User's Manual
Table Of Contents
- 1 Overview
- 2 Installation, wiring and debugging
- 3 Getting Started
- 4.Basic Functions
- 4.1 Management menu operations
- 4.1.1 Change Admin Password
- 4.1.2 Set or delete Super-open-password
- 4.1.3 Set admin card
- 4.1.4 Delete admin card
- 4.1.5 Set Machine Mode
- 4.1.6 Limits types of reading card
- 4.1.7 Restore to default settings
- 4.1.8 Add User
- 4.1.9 Delete user
- 4.1.10 Set open door methods
- 4.1.11 Set Multi-card to open door
- 4.1.12 Set lock working mode
- 4.1.13 Set Limits User Mode
- 4.1.14 Set Open-time
- 4.1.15 Set notification to close door
- 4.1.16 Set Alarm-time
- 4.1.17 Set Anti-dismantle alarm function
- 4.1.18 Set alarm or doorbell output function
- 4.1.19 Set Anti-crack function
- 4.1.20 Set LED indicator light mode
- 4.1.21 Adjust the brightness of the normally brigh
- 4.1.22 Set key backlit mode
- 4.1.23 Adjust brightness of key backlit
- 4.1.24 Set buzzer mode
- 4.1.25 Adjust key volume
- 4.1.26 Set the # key whether it can be used doorbe
- 4.1.27 Set doorbell key mode
- 4.2.28Set reader output format
- 4.2 Admin card or PIN operation
- 4.3Users operation
- 4.4 Other operations
- 4.5 Operation characteristics in different machine
- 4.1 Management menu operations
- 5 Management menu summary table
- 6 Precautions in use
- 7 Common troubleshooting
- 20 -
Note: When the machine is illegally dismantled, it alarms and an alarm signal will be send out at the same time. The alarm
can be canceled by inputting Admin Password, read admin card or user card.
4.1.18 Set alarm or doorbell output function
42, 0#, default value, alarm wire output alarm signal voltage.
42, 1#, alarm wire output doorbell signal voltage.
Note: The Alarm wire is internally connected with the drain of the NMOS tube, and the output is active low, which can drive
the current below 1A.
4.1.19 Set Anti-crack function
43, 0#, default value, normal working mode.
43,1#, alarm working mode, when error operation times more than allowed times, the machine alarm will beeps and it
send out alarm signal.
43, 2#, locked working mode, when error operation times more than allowed times, the machine will lock up for some
time. User cannot press any key or read card during that time.
44, (1-10)#, default value is 10, set maximum times for the error operation from 1 to 10 .
45, (1-99)#, default value is 10,set time locked after the error operation indicate maximum times, from1 to 99minutes.
Note: Anti-crack function refers to prevent illegal and unlimited password or card crack to open the door in a short period of
time, the basic method is within 10 minutes of invalid password or invalid card number read error exceeds the default setting,
the controller will alarm or lock up for some time.
4.1.20 Set LED indicator light mode
50, 0#, standby, LED indicator light is off.
50, 1#, default value, standby, LED indicator light always red.
50, 2#, standby, LED turns green in reader mode, LED turns red in other modes.
4.1.21 Adjust the brightness of the normally bright red indicator
51, 1, 1, ... ,decrease brightness
51, 2, 2, ..., increase brightness
Note: The brightness of the indicator light can be adjusted total 21 different levels. Each time you press the “1” key, it
decrease 1 level of brightness. Press and hold on the “1” key, the brightness will continuously decrease. When it reaches to
minimum level of brightness, the controller will beep twice. Each time you press the “2” key, it increase the level of brightness.
Press and hold on the “2” key, the brightness will continuously increase. When it reaches to the maximum brightness the
controller will beep twice.