User guide

CAMCORP, INC.
Phone: 913-831-0740 Fax: 913-831-9271
TROUBLESHOOTING THE CLEANING MECHANISM
1. Diaphragm Valve Pulsing Failure. The Diaphragm assembly consists of (3)
components. The main diaphragm valve, the secondary diaphragm valve, and the
solenoid valve. Troubleshooting recommendations as follows:
A. Main Diaphragm and Secondary Diaphragm:
1. Diaphragm Valve Bleeding Air Disassemble and inspect both
diaphragms for ruptured valves or air bleed holes are restricted.
(Reference attached manual) Replace with a repair kit if necessary.
2. Verify Positive Displacement Pump is operating correctly and producing
compressed air.
3. Verify weighted relief valve is weighted correctly allowing tank to build
7-8 PSI pressure.
B. Solenoid Valve:
1. Open or short circuit in wiring between timer and solenoid Check
continuity with ohmmeter or suitable tester and repair as required.
2. Plastic plug in solenoid exhaust port - Remove and discard plug.
2. Timer – Not Operating
A. Check for mechanical damage.
B. Check the wiring from the timer to the solenoids for open or short circuits.
C. Replace Timer.
11-1