ROUTINE MAINTENANCE
A. Inspection
Frequency will vary as widely as there are operating conditions. In general
proceed as follows:
1. Daily – Check unit differential pressure.
2. Weekly – Verify that the pulse arm drive and PD Pump are operating
properly.
3. Monthly Lubricate fan, rotary valve and screw conveyor. Check seals on
latter two for dust loss.
4. Quarterly On Top Access Units, check for dust accumulation in clean air
plenum.
B. Repairs
1. Filter bags – Generally replacement, although some applications can be
laundered.
2. Rotary Valves Usually a matter of periodic seal and blade replacement.
More detailed information is supplied with the valve.
3. Screw Conveyors Periodic replacement of “V” belts and shaft seals.
Inspect hanger bearings during filter bag change. Failure will be detected by
the squeal.
4. PD Pump “V” belt tension if running rough. Make sure rotor balance is
maintained.
1