Section 6 – Troubleshooting
-.5*(21)5-)+)-<-*3(
Symptom Possible cause Solution
Rotor does not rotate No power to motor Check breaker
Check motor heaters
Check motor starter
Rotor is jammed Inspect rotor and
remove object
Chain is broken Remove guard and
or has come off inspect drive
Faulty motor Remove chain and
or gear reducer
run motor with no
load
Excessive noise Bearings need Grease bearings,
grease replace if
necessary
Rotor has shifted Inspect rotor and
realign
Drive chain is rubbing Reposition chain
on chain guard or sprockets and
chain
Excessive air leakage Worn rotor wiper Inspect and replace
through airlock end
plate