Manual
Phone 800-323-2593
630-231-5900
Fax 630-231-1377
National Controls
Corporation
4
Contents
Previous
Next
4-12
Features
■Field Selectable from 2 to
10 Outputs
■Completely Solid-state
Timing and Switching
Logic
■300% Overrated Solid-
state Switch
■Pressure Switch Control
Option On Board
■12 to 24 Volts D.C. Input
Voltage
■Adjustable "On" and "Off"
Times
■High Quality Locking
Bushing Potentiometers
for Timing Adjustment
■Very Low Power
Consumption
■RTV Protective Coating
for Corrosion and
Moisture Resistance
■LEDs Show
Compartment Being
Cleaned
■Metal Chassis Provided
For Mounting Directly
Into NEMA-4 Enclosure
Operating Logic: The control can function in 2
modes:
Continuous Mode:The pressure switch terminals
are shorted. Upon application of output voltage,
the control activates output #1 after the preset off
time. It will continue to activate outputs sequen-
tially until input voltage is removed.
On Demand Mode:The pressure switch termi-
nals are connected to an isolated set of contacts of
a differential pressure switch. The control will acti-
vate the outputs sequentially whenever the pres-
sure switch contacts are closed. When the pressure
switch contacts open, the output sequencing stops.
Re-closing of the contacts will cause the control to
resume activating the outputs.
Program wire allows the user to select the maxi-
mum number of outputs to be activated.
DC Input, Pulse
Cleaning of bag
House Dust
Collectors Model
DNC-T2010-ADC
Dust Collector
Controls
No. of
Outputs
2 - 10 12 - 24 VDC 1.5 - 60 DNC-T2010-ADC
Input Voltage
Off Time
(In Seconds)
Part Number
Time Setting Ranges
On Time:Adjustable from 20 to 200 millisec-
onds
Off Time:Adjustable from 1.5 to 60 seconds
Repeatability:±3% over temperature & voltage
ranges
Input
Operating Voltage:10.0 to 29.0 VDC
(Unfiltered supply voltage must be full-wave
rectified.)
Power Consumption Voltage During Off
Time:1.5 Watts @ 12 VDC, 4.2 Watts @ 24
VDC
Output
Type:Solid-state switch
Load Per Output:3 Amp maximum @ 1.5 V
less than input voltage
Protection
Transient Input Voltage: Metal oxide varistor
plus large filter capacity
Transient Output Voltage:Solid-state switch
rated at 10 Amps. - 60 Volts fly-back diode pro-
tected
Short Circuit Protection:3 Amp fuse for circuit,
Reverse polarity protected
Environmental
Operating Temperature:-40°F to 150°F
(-40°C to 60°C)
Storage Temperature:-40°F to 185°F
(-40°C to 85°C)
Specifications
Click for Where to Buy