Owner's manual
MAINTENANCE AND SERVICE SPECIFICATIONS SHEET
RECOMMENDED LUBRICANTS AND CAPACITIES
15
MODEL RPM PRESSURE
PSI (mbar)
VACUUM
in. Hg (mbar)
TEMPERATURE RISE
F° (C°)
4504 4000 18 (1240) 16 (540) 290 (161)
4506 4000 18 (1240) 16 (540) 265 (147)
4509 4000 18 (1240) 16 (540) 260 (144)
4512 4000 15 (1035) 16 (540) 255 (141)
4604 4000 18 (1240) 16 (540) 290 (161)
4606 4000 18 (1240) 16 (540) 265 (147)
4609 4000 18 (1240) 16 (540) 260 (144)
4612 4000 15 (1035) 16 (540) 255 (141)
6012 3000 15 (1035) 16 (540) 280 (155)
6016 3000 15 (1035) 16 (540) 280 (155)
6024 3000 10 (690) 16 (540) 230 (127)
MAXIMUM OPERATING LIMITS
RECOMMENDED MINERAL BASED LUBRICANTS
RECOMMENDED SYNTHETIC BASED LUBRICANTS
AMBIENT
TEMPERATURE
TUTHILL EXXONMOBIL SHELL
0
o
F (-18
o
C) to
32
o
F (0
o
C)
SHC 626
(ISO 68)
MADRELA
®
AS 68
(ISO 68)
32
o
F (0
o
C) to
90
o
F (32
o
C)
PneuLube
(ISO 100)
SHC 627
(ISO 100)
MADRELA
®
P 100
(ISO 100)
90
o
F (32
o
C) to
120
o
F (50
o
C)
SHC 629
(ISO 150)
MADRELA
®
P 150
(ISO 150)
NOTE: Tuthill Vacuum & Blower Systems cannot accept
responsibility for damage to seals, O-rings and
gaskets caused by use of synthetic lubricants
that are not recommended by Tuthill Vacuum &
Blower Systems.
For best results, use PneuLube™ synthetic oil,
available from your Tuthill Vacuum & Blower
Systems Sales Professional.
RECOMMENDED MINERAL BASED, FOOD GRADE LUBRICANTS
AMBIENT
TEMPERATURE
Lubricant meeting U.S. FDA regulations 21 CFR
172.878 and 178.3620(a) for direct and indirect
food contact
Lubricant meeting U. S. FDA regulation 21 CFR
178.3570 governing petroleum products which may
have incidental contact with food, (formerly USDA H1)
0
o
F (-18
o
C) to
32
o
F (0
o
C)
CITGO CLARION
®
350 FOOD GRADE
(ISO 68)
CITGO CLARION
®
A/W 68
(ISO 68)
32
o
F (0
o
C) to
90
o
F (32
o
C)
CONSULT FACTORY CITGO CLARION
®
A/W 100
(ISO 100)
90
o
F (32
o
C) to
120
o
F (50
o
C)
CONSULT FACTORY CONSULT FACTORY
AMBIENT
TEMPERATURE
SHELL CITGO CHEVRON TEXACO EXXONMOBIL
0
o
F (-18
o
C) to
32
o
F (0
o
C)
TELLUS
®
PLUS 68
(ISO 68)
A/W 68
(ISO 68)
RANDO HD 68
(ISO 68)
DTE HEAVY MEDIUM
(ISO 68)
32
o
F (0
o
C) to
90
o
F (32
o
C)
TELLUS
®
PLUS 100
(ISO 100)
A/W 100
(ISO 100)
RANDO HD 100
(ISO 100)
DTE HEAVY
(ISO 100)
90
o
F (32
o
C) to
120
o
F (50
o
C)
TELLUS
®
PLUS 150
(ISO 150)
A/W 150
(ISO 150)
RANDO HD 150
(ISO 150)
DTE EXTRA HEAVY