Storage Recommendations (continued)
Isolation Dampers
All limit switches, solenoids, and air cylinder ports must be capped and
taped to prevent any moisture or dirt from entering.
Equipment can sit outside provided it is covered with a tarp and is on a
pallet or skid to keep it out of water and dirt.
Rotary Valve
Rotor and interior of valve should be well oiled with vegetable oil to
prevent rust and to maintain compatibility with product.
Unit can be stored outside provided it is covered with a tarp and is on a
pallet or skid to keep it out of water and dirt.
Reference rotary valve IOM manual for long-term storage.
Butterfly (Wafer Valve)
All limit switches, solenoids, and air cylinder ports must be capped and
taped to prevent any moisture or dirt from entering.
Unit can be stored outside provided it is covered with a tarp and is on a
pallet or skid to keep it out of water, dirt and sunlight.
Reference butterfly valve IOM manual for long-term storage.
Level Indicators
Store these items inside a protected cool dry area.
AC Inverters
Store these items and all other electrical controls inside a protected cool
dry area.