Service manual

15
2. To signal the dwell position for a cycle on de-
mand application. In cycling, the input is signaled
tostop somewhere in dwell position. This stopping may
be done either by stopping the motor or using a clutch
brake to disconnect the motor from indexer input. Ei-
ther, these methods allow operation of the Index Drive
near its rated capacity
(shortest motion time)
and, by
controlling the time the indexer stops, give the cus-
tomer his desired dwell time.
CAUTION: There are several ways to misapply the
limit switch. One of the most common problems is fail-
ure to stop the unit in dwell. Starting and stopping in
motion may overload the indexer and open up the
overload clutch (if supplied).
The dwell position can be found by checking the in-
dexer output for movement by means of an indicator
or by observing the appropriate notes in our CAMCO
assembly drawings.
CORRECT KEYWAY POSITION
FOR CAM AND LIMIT SWITCH ASSEMBLIES
HOW TO ORDER PARTS
Please refer to Parts List applicable to your specific model as shown in the specific model service
manual. This Parts List is for a standard Index Drive. If you feel your drive in nonstandard or you are in
doubt you should contact CAMCO Customer Service (847) 459-5200 and request a bill of material for
your specific unit (based on serial number).
You may order parts by using the Standard Bill of Material even if your unit is nonstandard CAMCO's
order entry people will review the closed order file based on the following information and supply you
with the correct part.
REQUIRED INFORMATION:
1. Original purchase order number (if available)
2. Customer name (original purchaser of drive)
3. Model number (located on name plate)
4. Serial number (located on name plate)
5. Approximate date of purchase
CAM & LIMIT SWITCH FUNCTIONS
THIS OPTION SERVES TWO PURPOSES:
1. Some customers desire an electrical signal somewhere during dwell in order to trigger another device
such as a cyclinder, punch press, loader, etc.
94