Product Manual
Table Of Contents
Cambricon®
Copyright © 2020 Cambricon Corporation
19
5.5 Air inlet temperature requirements
The required environment temperature of MLU290-M5 is 0-45 ℃ . The minimum air volume
requirements of radiator under main temperature conditions is shown in the table below:
51Figure 1. Minimum air volume requirement VS Air inlet temperature table for MLU290-M5
Air inlet temperature
(℃)
Radiator Minimum Air Volume
Requirements (CFM)
25 35
30 40
35 50
40 70
45 110
51Figure 1. Minimum air volume requirement vs Air inlet temperature