User's Manual
Table Of Contents
Cambricon Technologies, MLU270-S Series Intelligent Processing Card User Manual
Figure.5 Airflow Directions Support
2.6.4 MLU270-S Series Operating Temperature and Airflow Requirements
MLU270-S Series can support operating(TDP) at Temperature of 0-50 ℃ (Temperature at the
entrance of heatsink). Refer to below table for more information about minimum Airflow
requirement:
Table 9 MLU270-S Temperature of Ambient vs Min Airflow Requirement
Air Temperature at
Card Inlet(℃)
Min Airflow Requirements
(CFM)
30
3
35
3.5
40
4.3
45
5.4
50
6.7
55(not
recommend)
8