7.2Wind resistance curve of MLU-X1000
The system wind resistance curve of MLU-X1000 is shown below:
Figure 7.1 Wind resistance curve of MLU-X1000
Table 7.2 Air Volume VS Pressure Drop of MLU-X1000
Air volume (CFM)
Air pressure (Pa)
400
1737
360
1408
310
1044
260
735
0
0