User Manual

Table Of Contents
PMP 450 Planning Guide Network migration planning
pmp-0047 (December 2012)
2-5
Sector capacity
The following table exhibits the maximum aggregate sector throughput for several Cambium network deployments.
This table may be used as a reference for planning new networks or for planning network upgrades.
Table 8 Examples of aggregate sector throughput various air interfaces
Air Interface
Rate
Adapt
Ch BW
(MHz)
Cyclic
Prefix
Maximum
Aggregate Sector
Throughput - RF
Link Test (Mbps)
FSK (PMP 1x0 Series) 1x 20 N/A 7
FSK (PMP 1x0 Series) 2x 20 N/A 14
OFDM (PMP 430 Series) 1x 5 CP 1/16 4
OFDM (PMP 430 Series)
2x 5 CP 1/16 8
OFDM (PMP 430 Series)
3x 5 CP 1/16 12
OFDM (PMP 430 Series)
1x 10 CP 1/16 7
OFDM (PMP 430 Series)
2x 10 CP 1/16 15
OFDM (PMP 430 Series)
3x 10 CP 1/16 24
OFDM (PMP 430 Series)
1x 20 CP 1/16 15
OFDM (PMP 430 Series)
2x 20 CP 1/16 32
OFDM (PMP 430 Series)
3x 20 CP 1/16 50
OFDM (MIMO) (PMP 450 Series)
2x 10 CP 1/16 13
OFDM (MIMO) (PMP 450 Series)
4x 10 CP 1/16 26
OFDM (MIMO) (PMP 450 Series)
6x 10 CP 1/16 39
OFDM (MIMO) (PMP 450 Series)
2x 20 CP 1/16 30
OFDM (MIMO) (PMP 450 Series)
4x 20 CP 1/16 60
OFDM (MIMO) (PMP 450 Series)
6x 20 CP 1/16 98