Restoring, resetting and rebooting Chapter 7: Operation
7-26
UNDER DEVELOPMENT
phn-2182_003v004 (Oct 2011)
Resetting to default configuration (with country reset)
Use the reset plug (supplied in each PTP 250 ‘Link Complete’ or ‘End Complete’ kit) to
reset the unit to factory default configuration, including reset of the country of operation
(this will have to be reselected at first login after the reset).
When the unit is reset to default configuration, the current configuration is lost and the
unit reboots, causing loss of service.
To reset the unit to factory defaults without resetting the country of operation, follow the
procedure in Resetting to default configuration (without country reset) on page 7-25.
To reset to default configuration including country reset, proceed as follows:
1
Remove the ODU drop cable from the PoE power supply DATA & POWER OUT
port.
2
Plug the ODU drop cable into the reset plug and then plug the reset plug into the
PoE power supply DATA & POWER OUT port (Figure 7-13).
3
Wait for at least 45 seconds.
4
Disconnect the reset plug and re-insert the ODU drop cable into the PoE power
supply DATA & POWER OUT port.
5
The unit should now be reset to factory default settings, including the following:
Password ‘motorola’,
IP address ‘169.254.1.1’,
Master Slave Status ‘Slave’,
Country Code is blank.
6
To reconfigure the unit, follow the instructions in Connecting to the unit on
page
6-3 and Using the installation wizard on
page 6-13.
When logging into the unit, change Password and select Country Code (these will
be prompted).