User's Guide
Table Of Contents
- PTP 250 User Guide
- Safety and regulatory information
- Contents
- List of Figures
- List of Tables
- About This User Guide
- Chapter 1: Product description
- Chapter 2: Planning considerations
- Chapter 3: Legal information
- Chapter 4: Reference information
- Chapter 5: Installation
- Chapter 6: Configuration and alignment
- Chapter 7: Operation
- Chapter 8: Troubleshooting
- Testing link end hardware
- Testing when PoE LEDs do not illuminate correctly
- Testing after a lightning strike
- Test flowcharts
- AC LED is off
- AC LED is flashing
- PORT LED is off
- PORT LED is flashing
- Test Ethernet packet errors reported by ODU
- Test Ethernet packet errors reported by managed switch or router
- Test ping packet loss
- Test resistance in the ODU cable
- Testing the radio link
- Testing link end hardware
- Glossary
Equipment specifications Chapter 4: Reference information
4-2
UNDER DEVELOPMENT
phn-2182_003v004 (Oct 2011)
Equipment specifications
This section contains specifications of the ODU and power supply unit that are required for
PTP 250 installations.
ODU specifications
The ODU conforms to the specifications listed in Table 4-1, Table 4-2 and Table 4-3.
Table 4-1 Integrated ODU physical specifications
Category Specification
Dimensions Width 370 mm (14.5 in), Height 370 mm (14.5 in),
Depth 95 mm (3.75 in)
Weight 5.35 Kg (11.8 lbs) including bracket
Table 4-2 Connectorized ODU physical specifications
Category Specification
Dimensions Width 309 mm (12.2 in), Height 309 mm (12.2 in),
Depth 105 mm (4.01 in)
Weight 4.7 Kg (10.4 lbs) including bracket
Table 4-3 ODU environmental specifications
Category Specification
Temperature -40°C (40°F) to +60°C (140°F)
Wind loading 150 mph (242 kph) maximum. See Wind loading on page 2-7 for
a full description.
Humidity 100% condensing
Waterproofing IP66
UV exposure 10 year operational life (UL746C test evidence)