PTP 250 User Guide Grounding and lightning protection
phn-2182_002v000
May 2011
2-13
Basic requirements
The following basic protection requirements must be implemented:
The ODU must be in ‘Zone B’ (see Lightning protection zones on
page 2-11).
A lightning protection unit (LPU) must be installed within 600 mm (24 in) of the
point at which the drop cable enters the building or equipment room.
The drop cable must be bonded to the supporting structure in order to prevent
lightning creating a potential between the structure and cable, which could
cause arcing, resulting in fire risk and damage to equipment.
The drop cable must be grounded at the building entry point.
The drop cable must not be laid alongside a lightning air terminal.
All grounding cables must be a minimum size of 10 mm
2
csa (8AWG), preferably
16 mm
2
csa (6AWG), or 25 mm
2
csa (4AWG).
Grounding cable requirements
When routing, fastening and connecting grounding cables, the following requirements
must be implemented:
Grounding conductors must be run as short, straight, and smoothly as possible,
with the fewest possible number of bends and curves.
Grounding cables must not be installed with drip loops.
All bends must have a minimum radius of 203 mm (8 in) and a minimum angle of
90° (Figure 2-2). A diagonal r
un is preferable to a bend, even though it does not
follow the contour or run parallel to the supporting structure.
All bends, curves and connections must be routed towards the grounding
electrode system, ground rod, or ground bar.
Grounding conductors must be securely fastened.
Braided grounding conductors must not be used.
Approved bonding techniques must be used for the connection of dissimilar
metals.