User's Guide Part 2

User Guide: PTP 600 Series Installing PTP-SYNC
phn-0896_009v003
Feb 2010
UNDER DEVELOPMENT
5-39
Connecting up PTP-SYNC
To connect the PTP-SYNC to the PIDU, ODU, GPS receiver (if fitted), and LPU (if
fitted), proceed as follows:
Procedure 5-13 Weather-proof the GPS receiver module cable
1
Use a one meter un-screened CAT5e Ethernet cable (refer to
Cables and
connectors
on page 1-15) and connect the PIDU to the PTP-SYNC.
2
If using a GPS timing reference, install the GPS unit as described in
Installing
the GPS receiver for PTP-SYNC
on page 5-28) The GPS receiver unit can
either be wall mounted or mounted on a metal tower or mast.
3
Use the supported Superior Essex cable. Connect the cable to the GPS receiver
unit.
4
Connect the GPS receiver module via an LPU, or the chosen 1PPS timing source,
to the PTP-SYNC.