User's Guide Part 2

Checking the configuration Chapter 5 Installation
phn-0896_009v003
5-2
UNDER DEVELOPMENT
Feb 2010
Checking the configuration
This section describes how to configure the management PC, power up the unit,
connect it to the PC and check the factory configuration. Motorola recommends that
these tasks should be performed before site installation.
IP addresses of the Master and Slave units
The PTP 600 is supplied as a pair of matched units, a Master and a Slave. The usual
default IP addresses are:
Master: 169.254.1.2
Slave: 169.254.1.1
However, some units may have been configured with different IP addresses:
Master: 10.10.10.11
Slave: 10.10.10.10
Configuring the IP interface on the PC
Before powering up the unit, set up the IP configuration of the management PC.
If the default IP addresses of the Master and Slave units are 169.254.1.2 and
169.254.1.1, then set up the IP configuration of the PC as follows:
Enter an IP address of 169.254.1.n, where n is any value between 3 and 254. Do
not use 169.254.1.1 or 169.254.1.2.
Enter a subnet mask of 255.255.0.0.
If the default IP addresses of the Master and Slave units are 10.10.10.11 and
10.10.10.10, then set up the IP configuration of the PC as follows:
Enter an IP address of 10.10.10.n, where n is between 2 and 254. Do not use
10.10.10.10 or 10.10.10.11.
Enter a subnet mask of 255.255.0.0.