Example PTP 500 Series Configuration
Data
For your convenience these two units have been
pre-configured as a link Units
Units:
ODU serial number ODU serial number
0167100000A0 016710000096
Ethernet MAC address Ethernet MAC address
00:04:56:10:00:96 00:04:56:10:00:A0
Configured as:
Master Slave
Target MAC address Target MAC address
00:04:56:10:00:A0 00:04:56:10:00:96
License key License Key
0557-D8B0-47A1-B0DD 534F-4F54-D1B0-E2DA
IP Address IP Address
169.254.1.2 169.254.1.1
Table 12 500 Series Bridge
Factory Configuration Values
The factory default configuration is limited in range to 40 Km (25 miles). If you wish to install a
wireless link with a range of > 40 Km (> 25 miles) and < 200 Km (< 124 miles) or < 5Km(< 3
miles) you must follow the steps in Section 8.3.4.1 “Manually Configuring The Wireless Units”.
The factory default configuration is set to Region 26. Region 26 allows the 500 Series bridge a
maximum transmit power of 25 dBm. If the local regulatory regime limits the maximum transmit
power (EIRP) to less than 25 dBm you should obtain a new license key containing the correct
region code from your local distributor or direct from Motorola. Alternatively in the short term,
you should reduce the maximum transmit power by following the procedures in Section 8.3.4.1
“Manually Configuring The Wireless Units”.
8.3.4.1 Manually Configuring The Wireless Units
If the installer / system administrator wishes, they may modify the default installation configu-
ration. If only the IP addresses (network configuration) are incorrect it is recommended that the
values are changed via the configuration menu (Section 8.3.1.2 “LAN Configuration Page”). If