User Manual
Installation
52
Should it be necessary to disconnect the PIDU Plus to ODU cable at the ODU, this can be
achieved by removing the weather proofing gland and depressing the RJ45 locking tab with a
small screwdriver as shown below:
Figure 22 Disconnecting the ODU
CAUTION: Ensure that power is removed from the system at the PIDU Plus to prevent damage
to the ODU while making or breaking the connection.
7.7.4 Routing the Cable
After connecting the cable to the ODU it can be routed and secured using standard cable routing
and securing techniques. When the cable is in place it can then be cut to the desired length at the
PIDU Plus prior to connection to the PIDU Plus
7.7.5 Fitting a Lightning Protection Unit
If you have opted to fit a Lightning Protection unit, this should be installed by following the
manufacturer’s instruction. For recommended types see Section 11 "Lightning Protection”
7.7.6 Grounding the Installation
The Outdoor Unit (ODU) must be properly grounded to protect against power surges. It is the
user’s responsibility to install the equipment in accordance with Section 810 of the National Electric
Code, ANSI/NFPA No.70-1984 or Section 54 of the National Electrical Code in the country of
installation. These codes describe correct installation procedures for grounding the outdoor unit,
mast, lead-in wire and discharge unit, size of grounding conductors and connection requirements
for grounding electrodes. It is recommended that installation of the outdoor unit be contracted to
a professional installer.