Chapter 1: Product description System management
Note
When Recovery has been entered through a power on/off/on cycle, the ODU will revert
to normal operation if no web access has been made to the unit within 30 seconds.
This prevents the unit remaining inadvertently in recovery following a power outage.
Recovery mode options
Options in recovery mode (IPv4 only) are as follows:
Load new main application software.
Reset all configuration data. This option resets IP and Ethernet configuration, and erases
(zeroizes) critical security parameters.
Reset IP and Ethernet configuration.
Erase (zeroize) critical security parameters.
Reboot with existing software and configuration.
Note
If recovery mode has been entered because of a checksum error, after a 30 second
wait the ODU will attempt to reboot with existing software and configuration.
The recovery software image is installed during manufacture of the ODU and cannot be upgraded
by operators.