Table 1
Main characteristics of the
PTP 650 Series
Characteristic
Value
Topology PTP
Wireless link condition LOS, near LOS or non-LOS
Range Up to 200 km
Duplexing TDD (symmetric and asymmetric)
Connectivity Ethernet
Operating frequencies 4.9 to 6.0 GHz
Channel bandwidth 5, 10, 15, 20, 30, 40 or 45 MHz
High spectral efficiency Up to 10 bps/Hz
Data rate Up to 450 Mbps (45 MHz channel BW)
Frequency bands
The PTP 650 ODU can be configured by the user to operate in the following bands:
• 4940 to 4990 MHz
• 5150 to 5250 MHz
• 5250 to 5350 MHz
• 5470 to 5725 MHz
• 5725 to 5875 MHz
Page