User's Manual Part 1

Table Of Contents
Chapter 3: System planning Radio spectrum planning
Radio spectrum planning
This section describes how to plan PTP 650 links to conform to the regulatory restrictions that
apply in the country of operation.
Caution
It is the responsibility of the user to ensure that the PTP product is operated in
accordance with local regulatory limits.
Note
Contact the applicable radio regulator to find out whether or not registration of the
PTP 650 link is required.
General wireless specifications
Table 30 lists the wireless specifications that apply to all PTP 650 frequency bands. Table 31 lists
the wireless specifications that are specific to a single frequency band.
Table 30
PTP 650 wireless specifications (all variants)
Item
Specification
Channel selection Manual selection (fixed frequency).
Dynamic frequency selection (DFS or DFS with DSO) is available
in radar avoidance regions.
Manual power control To avoid interference to other users of the band, maximum
power can be set lower than the default power limit.
Integrated antenna type 23 dBi Flat plate antenna (PTP 650) or 19 dBi Flat plate antenna
(PTP 650s).
Duplex schemes Symmetric fixed, asymmetric fixed and, for the Full variant only,
adaptive TDD.
Range Optical Line-of-Sight: 200 km (125 miles).
Non-Line-of-Sight: 10 km (6 miles).
Over-the-air encryption AES 128-bit or 256-bit.
Weather sensitivity Sensitivity at higher modes may be reduced by adjusting the
Adaptive Modulation Threshold.
Error Correction FEC
Page