User's Manual

Table Of Contents
7 Installation
106
7.6 Mounting the ODUs
7.6.1 Mounting Bracket
The ODU is pre-fitted with a mounting bracket (designed to ease installation) and with earth bonding
leads (Figure 36).
Figure 36 –
ODU with Mounting Bracket and Earth Bonding Leads
WARNING: When mounting the ODU, observe the following precautions against failure of the
assembly:
Do not remove the pre-fitted mounting bracket from the ODU.
Do not mount the ODU on poles with diameter less than 50mm (2”) or greater than 75mm
(3”). The ODU mounting bracket is designed to work only with poles with diameter in the
50 mm (2”) to 75 mm (3”) range.
Do not over-tighten the bolts.