Specifications

Table 1 Supported components
Host feature
Requirement
Platform IBM RS/6000 (PCI bus only)
Operating systems
AIX 5.1, AIX 5.2, or AIX 5.3
Secure Path software kit HP StorageWorks Secure Path 2.0D Service Pack 3 for IBM AIX
Storage systems
HSG80 RAID storage systems with dual controllers running ACS
HSV100 RAID storage systems with dual controllers running VCS 3.014
or later
HSV110 RAID storage systems with dual controllers running VCS 3.014
or later
Solution software kit HP StorageWorks Solution Software 8.7 for IBM AIX
HP StorageWorks IBM AIX Kit for Enterprise Virtual Array for your EVA
version
Host bus adap
ters
PCI Adapter,
197819-B21 (DS-SWIA1-PD),
PCI Adapter,
197819-B22 (DS-SWIA2-PD), or
Cambex Fibre
Quik PC2000
FC interconnect hardware
See the HP StorageWorks SAN design reference guide for the latest
supported adapters and switches.
Coexistence with other multipathing products
Secure Path 2.0D Service Pack 3 for IBM AIX functions in a storage area network (SAN) environment with
other HP multipathing products, such as Secure Path for SUN Solaris, Secure Path for Windows®, Secure
Path for HP-UX, and Secure Path for XP and VA, as defined and described in the HP StorageWorks SAN
design reference guide, which can be downloaded from this HP web site:
h
ttp://h18006.www1.hp.com/products/storageworks/san/documentation.html
Secure Path operational features
Hardware prerequisites for Secure Path
Two paths must exist between each server and storage system. Each path must include a separate:
Fibre Channel (FC) switch
HSG80, HSV100, or HSV110 controller
FC host bus adapter (FC HBA)
NOTE:
On systems that support multiple I/O boards, HP recommends that you install each HBA on a
separate I/O board. Doing so eliminates the I/O board as a single point of failure.
Configure your RAID storage systems for FC fabric connectivity in Multiple-bus failover mode.
LUN support
Secure Path 2.0D Service Pack 3 for IBM AIX supports a maximum of four RAID systems per adapter
pair, and eight adapter pairs per server. Each array supports 32 LUNs per adapter pair, one of which is
the command console LUN (CCL). A total of 1024 LUNs (992 LUNs plus 32 CCLs )is supported.