Installation guide
96107 Fourth Edition 29
StorageTek Proprietary
Overview
• If using inband storage management, run the following command.
SMagent stop
• If using Cambex DPF failover driver, run the following command.
stopsrc -s cbxdpfar
• Determine the Cambex adapter name (fscsi(n)) (or IBM name fcs(n)) by
using the lsdev –Cc adapter command. Locate the name by finding the
Camber or IBM adapter entries. In the following examples, fscsi4 and
fscsi5 are the Cambex adapters and fcs0 is an IBM adapter.
fscsi4 Available 20-58 Cambex Fibre Channel I/O Controller
fscsi5 Available 20-60 Cambex Fibre Channel I/O Controller
fcs0 Available10-68 Fibre Channel Adapter
• Remove the adapters and scsi devices using the rmdev –Rdl fscsi(n)
Or fcs(n) for IBM.
Examples:
# rmdev –Rdl fscsi4
hdisk1 deleted
hdisk2 deleted
hdisk3 deleted
fscsi4 deleted
# rmdev –Rdl fscsi5
hdisk4 deleted
hdisk5 deleted
fscsi5 deleted
• If using inband storage management, run the following command.
SMagent start
• If using Cambex DPF failover driver, run the following command.
startsrc -s cbxdpfar