Tus neeg siv phau ntawv

3. Technical specifications
Sample rate: 1 Hz
Wind Speed
Range : Range: 0 to 45 m/s (1.12 to 100 mph)
Accuracy: ±0.1 m/s at 10m/s (0.22 at 22.4 mph)
Threshold: 1 m/s (2.24 mph)
Wind direction
Range: 0 - 359º
Accuracy: ±1º
Lateral and inferior female thread. It can be mounted either
on a plate (inferior screws) or on a tube (lateral screws).
A wide range of accessories can be used with the device.
The ULP can be mounted on a flat service and screwed on
to different sizes of poles. It can also be used with an
adaptor for poles of 39 mm.
* Please, visit our website and check all the accessories
available and their possible combinations.
05/07
ULTRASONIC ULP
User manual
3.5 Wind Information
· Wind speed
· Wind direction
3.7. Mounting accessories
3.6. Easy mount
- 3 x M4 lateral female thread
- 3 x M4 inferior female thread
Noth mark position
Make sure the north mark
is perfectly aligned.