Manual
Table Of Contents
- Start Up Guide
- Getting Started
- Checklist
- 1. Power up the Core and connect a PC
- 2. Access the basic Core configuration
- 3. Install a Software Upgrade Licence key (Optional)
- 4. Configure the Core for Surface Panels
- 5. Configure Network Switches & Devices
- 6. Configure Surface panels ID, IP addresses & Subnet masks
- 7. Connect Surface Switch & Surface Panels to the Core
- 8. Access Assist setup and create a new show
- 9. Connect to Assist from the Studio or Management subnets
- 10. Upload control layouts to the soft panels
- 11. Create layouts with Type R Soft Panel Designer
- 12 Update System Software & AoIP Devices Firmware
- 13. Configure AoIP Port & Connect server IP addresses
- 14. Connect Audio Switch and AoIP Ports to the Core
- Surface Panels - Suggested Settings
- AoIP Network Interfaces - Suggested Settings
- About Type R manuals
- User Notes
23
1. Connect the audio network switch(es) to interfaces 5 (& 6) on the rear of the core (marked “Surface”) ,
Then follow the steps given below to configure each AoIP interface in an IO box or core:
2. Connect the Pri & Sec AoIP interfaces on the rear of the IO box or core, to your network switch or switches.
Note: Follow the suggested switch port connections given for your network switch(es) in the corresponding Network
Device document if unsure (see section 6).
Note: PTP aware switches are recommended, but are not necessary for small AoIP networks
Note: Connect one IO box / device or core at a time to avoid IP address conflicts.
EXAMPLE OF CONNECTING A COMBO AOIP BOX TO THE CORE VIA AN AOIP SWITCH
14. CONNECT AUDIO SWITCH AND AOIP PORTS TO THE CORE
3. Enter 172.16.255.60 in the Google Chrome address bar and press enter to navigate to Calrec Connect.
4. Select Devices in the menu on the left and select the corresponding entry for the connected IO box / device or core.
5. In the settings area to the right, select the Interfaces tab.
6. Edit the IP address and subnet mask settings of eth1 and eth2 to your preferred values.
Note: Please refer to “AoIP Network Interfaces - Suggested Settings” on page 29 of this document for
suggested settings and reference tables.
7. Connect the next IO device and repeat steps 3, 4 & 5.
Once all IO box & core AoIP device network interfaces are known to be set with unique IP addresses, they may all be connected to
the same network. All IO boxes in the same subnet should be discovered and displayed in Calrec Connect as shown on the next
page for the Type R Core which has two AoIP device interfaces and a Combo AoIP device which has one AoIP device. Transmitter
and receiver streams may now be configured have Audio Inputs and Outputs patched to those streams and routed between
devices.
Please refer to the Further Reading section at the back of this guide for links to additional guidance about using Calrec Connect.