User Guide

INSTALLATION
THERMO-SENSORS
1. Using duct tape, attach the Over Limit thermo-sensor (marked with red) to the central area of
the upper-most heating element. Locate the sensor approximately 1-1/2 ft/450 mm from the
cord end of the heating element.
2. Using duct tape, attach the Maintenance thermo-sensor directly to the tank wall approximately
6 inches/150 mm from the bottom-most heating element.
CONTROL UNIT ON TANK WALL
If the control unit is located on the tank itself, finish tightening the
strap so that the box is secured in place.
CONTROL UNIT REMOTE LOCATION
If the control unit is located remotely from the tank, attach the con-
trol unit, using standard electrical practices, to any suitable surface,
pole, etc.
Note
Make sure that the strap does not cross any heating elements, power cords or thermo-
sensor leads.
Note
Standard lead lengths on the thermo-sensors and heating elements are 20 ft/6 m and
8 ft/2.5 m respectively. When locating the control unit, ensure that the thermo-sensor
wires and heating element power cords are not stretched taut and do not cross over
the heating elements.
4
Over Limit Sensor
Over Limit Sensor
Maintenance Sensor
Maintenance Sensor