RADIANT CEILING HEATING SYSTEM & WARM FLOORS COMFORT SYSTEM Operating Manual CM1002 — 2003-10-01
INTRODUCTION The Calorique Radiant Ceiling Heating (RCH) or Warm Floors System installed in your home is the finest heating system available. The RCH system is located above your home’s ceilings gently heating the occupants and furnishings in your home with even, comfortable radiant heat that never overheats the air — this results in large energy savings over any other electric-based heating system.
The Calorique Systems are made up of four major components: the heating panels, the wiring, the control device and the ceiling or floor structure. These components work together to create a system that provides comfortable, trouble-free heating. OPERATION Operation of both the RCH and Warm Floors systems is the same as with other heating systems: set the thermostat to the desired temperature and the system warms the room.
• Never cover any heated portion of a ceiling with decorative beams, track lighting, trim or other objects. This may trap heat and create a potential for overheating. • If new walls or partitions are added in contact with heated portions of a ceiling, the heating panels which are covered must be disconnected from power to avoid a potential for overheating. Note that additional heating panels may have to be installed to compensate for the disconnected panels.
Resistance Charts Calorique Radiant Ceiling Heating System Panels 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 RCH13P13W240V Resistance Power From … To 26 watts 2105 … 2437 52 1052 … 1218 78 702 … 812 104 526 … 609 130 421 … 487 156 351 … 406 182 301 … 348 208 263 … 305 234 234 … 271 260 210 … 244 286 191 … 222 312 175 … 203 338 162 … 187 364 150 … 174 390 140 … 162 416 132 … 152 442 124 … 143 468 117 … 13
Resistance Charts Calorique Warm Floors Comfort System Panels 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 FLR13P8W120V Resistance Power From … To 16 watts 855 … 990 32 428 … 495 48 285 … 330 64 214 … 247 80 171 … 198 96 143 … 165 112 122 … 141 128 107 … 124 144 95.0 … 110 160 85.5 … 99.0 176 77.7 … 90.0 192 71.3 … 82.5 208 65.8 … 76.2 224 61.1 … 70.7 240 57.0 … 66.0 256 53.4 … 61.9 272 50.3 … 58.2 288 47.
Resistance Charts Calorique Warm Floors Comfort System Panels 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 FLR17P10W120V Resistance Power From … To 20 watts 684 ... 792 40 342 ... 396 60 228 ... 264 80 171 ... 198 100 137 ... 158 120 114 ... 132 140 97.7 ... 113 160 85.5 ... 99.0 180 76.0 ... 88.0 200 68.4 ... 79.2 220 62.2 ... 72.0 240 57.0 ... 66.0 260 52.6 ... 60.9 280 48.9 ... 56.6 300 45.6 ... 52.
Resistance Charts Calorique Warm Floors Comfort System Panels 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 FLR25P17W120V Resistance Power From … To 34 watts 402 ... 466 68 201 ... 233 102 134 ... 155 136 101 ... 116 170 80 ... 93 204 67 ... 78 238 57.5 ... 67 272 50.3 ... 58.2 306 44.7 ... 51.8 340 40.2 ... 46.6 374 36.6 ... 42.4 408 33.5 ... 38.8 442 31.0 ... 35.8 476 28.7 ... 33.3 510 26.8 ... 31.