ENTRY DESCRIPTION
front panel using the ENTER key.
BUS Bus mode. The transient system is started by a bus
command or a group execute trigger (GET).
EXT External mode. The transient system is started by a
user-provided external TTL trigger signal on
TRIGGER IN1.
TRAN STEP Indicates the transient system execution mode. Available modes
are:
AUTO When triggered, the transient system will
automatically execute each list point sequentially
execution is paced by the dwell time set for each
d
without waiting for a trigger between list points. This
ata point.
ONCE W ute
the first list point and wait for a new trigger once the
d
o
hen triggered, the transient system will exec
well time expires. This allows triggered execution
f each step in the transient list.
List parameters:
VOLT # VStep oltage set point
VSLEW # VStep oltage slew rate in V/sec
FREQ # FStep requency set point
FSLEW Step # Frequency slew rate in Hz/sec
FUNC Step # W
Square, Clipped or any of the user provided
w
aveform selection. Available choices are Sine,
aveforms in waveform memory.
PAUSE ep # DSt elay
CURR Step # Current set point
PHASE Step # P
cl
hase angle set point. (Not relevant for phase A if
ock mode is internal.)
DWELL Step # Dwell time in seconds.
Range is 0.001 to 900000
TTLT ep # O
st
O
T
St N: Generates an output trigger pulse at this list
ep.
FF: No output trigger.
he out
p
ut tri
gg
er is available on the TRIG OUT1
California Instruments 65