User manual

User Manual – Rev B FCS Series II
units.
Notes: External Trigger input is standard.
External Trigger input and External sync are mutually exclusive.
Units with -LKS (auxiliary) cannot have External Sync.
2.6.1 -HV Option - Supplemental Specifications
Specifications for FCS units with -HV voltage range option installed are same as standard FCS
except where noted below.
Frequency
Range: 45 Hz - 1200 Hz
Voltage:
Ranges (L-N):
Low range 0 - 156 Vrms
High range 0 - 312 Vrms
Current
Model FCS18-1-HV (single phase) FCS18-3-HV (three phase)
156 V Range. 115.2 Arms 38.4 Arms
312 V Range. 57.6 Arms 19.22 Arms
Note: Current derates linearly from 50% of voltage range to 20% of specified current at 10% of
voltage range.
Note: Current, maximum amps per phase available. For FCS36/2, currents are times two. For
FCS54/3, currents are times three. 35° C ambient max.
Repetitive Peak Current
156 V Range. 325 Apk 108 Apk
312 V Range. 162 Apk 54 Apk
California Instruments 22