User manual

User Manual – Rev B FCS Series II
2.6 Available Options
AC Input Voltage Options
Line input: Must be specified at time of order. Refer to section 3.4.1
- 208 208V L-L AC nominal, 3 phase
- 240 240V L-L AC nominal, 3 phase
-380 380V L-L AC nominal, 3 phase
-415 415V L-L AC nominal, 3 phase
-480 480V L-L AC nominal, 3 phase
Output Options
- HV 156 / 312 V range output
- EHV 200 / 400 V range output
-LF Low frequency option. Limits maximum output frequency to 500 Hz.
-MODE Adds single phase and three-phase mode switching capability to FCS18-
3 models. Not available on FCS18–1 or FCS36-3 and FCS54-3 models.
Firmware Options
- 160 RTCA/DO-160D test firmware.
Includes RCTA-DO160D, section 16, Change #2 and EURO/CAE-14D
AC tests only.
- 704 Mil Std 704 test firmware – MIL704
Includes AC tests for Revisions D and E
- 704F Mil Std 704 test firmware – MS704
Includes AC tests for Revisions A through F
-ABD Airbus ABD0100.1.8 Tests. – ABD
Includes tables A, B and C.
This option can only be used with the provided LxGui Windows software.
-AMD Airbus AMD24C Tests. – AMD
Revision C.
This option can only be used with the provided LxGui Windows software.
-B787 Boeing 787B3-0147 Tests. – B787
This option can only be used with the provided LxGui Windows software.
Misc. Options
-ADV Advanced features package. Adds arbitrary waveform generation and
harmonic analysis measurements.
-EXS External Sync (see Notes)
-LAN Ethernet LAN interface connection. RJ45 connector.
Note: When installed, RS232C interface is disabled.
-LKM Clock and Lock Master. Enables synchronizing outputs of two AC
sources, one acts as master.
This mode supports a frequency range of 45 to 819 Hz. See section 3.9.
-LKS Clock and Lock Auxiliary. See -LKM for details. (See Notes, see section
3.9.)
-MB Multi-box option. Provides additional controller(s) on FCS36/2 or FCS54/3
confi
g
urations allowin
g
s
y
stem to be se
p
arated into individual functional
California Instruments 21