User manual

User Manual – Rev B FCS Series II
Number Message String Cause Remedy
limit" user define
ape is to
uld dama
amplifier ou
stage.
d wave
fundamental frequency programmed.
sh
co
o high and
ge
tput
823 "Amplifier fault" An amplifier failure.
n be reported at
y time.
Determine which amplifier is at fault
with self-test or checking LED on
Relay Board. Replace amplifier.
Ca
an
824 “Auxiliary down” One or mor
units is not
up or not wo
e auxiliary
Turn on all auxiliary units.
powered
rking.
825 “Over voltage prot trip” Over voltage
detected on output
Check output voltage for correct RMS
value.
826 “Peak current prot trip” Peak current limit
exceeded.
Peak current exceeded. Could be
caused by switching EUT on or off.
827 “Frequency error” Frequency error
during self-test.
Correct frequency was not measured
during self-test. May be result of 801
error.
828 “Phase error” Self test error phase
angle
Correct phase angle was not
measured during self-test. May be
result of 801 error.
829 “Dc component exceed
limit”
Too much DC content
in loaded ARB
waveform.
Check waveform programming.
Table 15-1: Error Messages