User manual
User Manual – Rev B FCS Series II
SXF 401 Tests – Revision F
SXF401 Emergency SS Limits Volt and Freq. Rev F
Condition Duration (s)
Nominal Voltage
A Vnom=115V, Fnom=60 Hz - Nominal 1800
B Vnom=115V, Flow=59.5 Hz - Nominal 1800
C Vnom=115V, Fhigh=60.5 Hz - Nominal
Low Voltage
D Vlow =105V, Fnom=60 Hz - Low 1800
E Vlow=105V, Flow= 59.5 Hz- Low 1800
F Vlow=105V, Fhigh=60.5 Hz - Low 1800
High Voltage
G Vhigh=125V, Fnom=60 Hz - High 1800
H Vhigh=125V, Flow=59.5 Hz- High 1800
I Vhigh=125V, Fhigh=60.5 Hz - High 1800
SXF 501 Tests
SXF
Starting operations are not applicable to AC Utilization Equipment.
601 Tests – Revision F
SXF601 Power Failure - One Phase
Condition Duration (s)
A 100 msec 52
B 500 msec 54
C 2 sec 66
SXF 602 Tests – Revision F
Not applicable for single-phase EUT’s.
SXF 603 Tests – Revision F
SXF603 Power Failure – Phase Reversal
Condition Duration (s)
N/A Use physical L-N connection reversal
Apply Vnom = 115 V, Fnom = 60 Hz
1800
California Instruments 190