User manual

User Manual – Rev B FCS Series II
11.7.5 SXF Group Tests
Single phase 60 Hz AC tests
Note: 0 Hz f rt of revision F only. There are no equivalent t in 6 requency tests are pa ests
revision A through E.
SXF 102 T ts – Res evision F
SXF102 Steady State Voltage and Frequency - Rev C-F
Condition Duration (s)
Nominal Voltage
A Nominal Vnom=115V, Fnom=60 Hz - 1800
B Vnom=115V, Flow=59.5 Hz - Nominal 1800
C Vnom=115V, Fhigh=60.5 Hz - Nominal 1800
Low Voltage
D Vlow =105V, Fnom=60 Hz - Low 1800
E Vlow=105V, Flow= 59.5 Hz- Low 1800
F Vlow=105V, Fhigh=60.5 Hz - Low 1800
High Voltage
G Vhigh=125V, Fnom=60 Hz - High 1800
H Vhigh=125V, Flow=59.5 Hz- High 1800
I 1800 Vhigh=125V, Fhigh=60.5 Hz - High
SXF 103 Tests
Voltage Phase Difference tests do not apply for single-phase EUT’s.
SXF 104 Tests – Revision F
SXF104 Voltage Modulation Rev F
Condition Duration (s)
A 1800 Vmod F = 1.0 Hz, V = 0.375 Vrms
B Vmod F = 1.5 Hz, V = 2.5 Vrms 1800
C Vmod F = 4 Hz, V = 2.5 Vrms 1800
D 1800 Vmod F = 10 Hz, V = 0.375 Vrms
E Vmod F = 15 Hz, V = 0.375 Vrms 1800
F Vmod F = 30 Hz, V = 0.375 Vrms 1 800
SXF 105 T ts – Res evisions E, F
SXF105 Frequency Modulation Rev F
Condition Duration (s)
A Fmod F = 0.1 Hz/sec, Fmod Amp = 0.5 Hz± 0.25 Hz 1800
B Fmod F = 0.5 Hz/sec, Fmod Amp = 0.5 Hz± 0.25 Hz 1800
C Fmod F = 4 Hz/sec, Fmod Amp = 0.5 Hz± 0.25 Hz 1800
D Fmod F = 25 Hz/sec, Fmod Amp = 0.5 Hz± 0.25 Hz 1800
E Fmod F = 15 Hz/sec, Fmod Amp = 0.5 Hz± 0.25 Hz 1800
California Instruments 186