User manual

User Manual – Rev B FCS Series II
SVF 401 Tests – Revision F
SVF401 Emergency SS Limits Volt and Freq. Rev F
Condition Duration (s)
Balanced Nominal Voltage
A Vnom, 360 Hz 1800
B Vnom, 400 Hz 1800
C Vnom, 600 Hz 1800
D Vlow, 800 Hz 1800
Balanced Low Voltage
E 108V, 360 Hz 1800
F 108V, 400 Hz 1800
G 108V, 440 Hz 300
H 108V, 480 Hz 300
I 108V, 520 Hz 300
J 108V, 560 Hz 300
K 108V, 600 Hz 1800
L 108V, 520 Hz 300
M 108V, 540 Hz 300
N 108V, 560 Hz 300
O 108V, 570 Hz 300
P 108V, 580 Hz 300
Q 108V, 600 Hz 1800
R 108V, 640 Hz 300
S 108V, 680 Hz 300
T 108V, 720 Hz 300
U 108V, 760 Hz 300
V 108V, 800 Hz 1800
oltage Balanced High V
W 118V, 360 Hz 1800
X 118V, 400 Hz 1800
Y 118V, 440 Hz 300
Z 118V, 480 Hz 300
AA 118V, 520 Hz 300
BB 118V, 560 Hz 300
CC 118V, 600 Hz 1800
DD 118V, 520 Hz 300
EE 118V, 540 Hz 300
FF 118V, 560 Hz 300
GG 118V, 570 Hz 300
HH 118V, 580 Hz 300
II 118V, 600 Hz 1800
JJ 118V, 640 Hz 300
KK 118V, 680 Hz 300
LL 118V, 720 Hz 300
MM 118V, 760 Hz 300
NN 118V, 800 Hz 1800
Unbalanced Nominal Voltage
N/A
SVF 501 Tests
Starting operations are not applicable to AC Utilization Equipment.
California Instruments 176