User manual

User Manual – Rev B FCS Series II
SVF 301 Tests – Revision F
SVF301 Abnormal SS Limits Volt and Freq Rev F
Condition Duration (s)
age Low Volt
A Vlow 100V, Fnom 400 Hz 1800
B Vlow 100V, Flow 360 Hz 1800
C Vlow 100V, Fhigh 600 Hz 1800
D Vlow 100V, Fhigh 800 Hz 1800
High Voltage
E Vhigh 125V, Fnom 400 Hz 1800
F Vhigh 125V, Flow 380 Hz 1800
G Vhigh 125V, Fhigh 600 Hz 1800
H Vhigh 125V, Fhigh 800 Hz 1800
SVF 302 Tests – Revision F
SVF302 Abnormal Voltage Transients. Rev F
Condition Duration (s)
Run at 400, Repeat at 360, 600 and 800 Hz
Over Voltage
A 140Vrms, 180 msec, tf < 0.5 cyc, tr < 0.5 cyc 52
B 140Vrms, 180 msec, tf < 0.5 cyc, tr = 87 ms
then 135Vrms, ramp down, tr = 253 msec
then 130Vrms, ramp down, tr = 6.41 sec
then 125Vrms, ramp down, tr > 10 sec
then 115Vrms.
135
C 160Vrms, 78 msec, tf < 0.5 cyc, tr < 0.5 cyc 54
D 160Vrms, 78 msec, tf < 0.5 cyc, tr = 31 ms
then 150Vrms, ramp down, tr = 71 msec
then 140Vrms, ramp down, tr = 87 sec
then 135Vrms, ramp down, tr > 253 sec.
then 130Vrms, ramp down, tr = 6.41 sec
then 125Vrms, ramp down, tr > 10 sec
then 115Vrms.
135
E 180Vrms, 50 msec, tf < 1.25 ms, tr < 1.25 ms 52
F 180Vrms, 50 msec, tf < 0.5 cyc, tr = 11 ms
then 170Vrms, ramp down, tr = 17 msec
then 160Vrms, ramp down, tr = 31 msec
then 150Vrms, ramp down, tr = 71 msec
then 140Vrms, ramp down, tr = 87 sec
then 135Vrms, ramp down, tr > 253 sec.
then 130Vrms, ramp down, tr = 6.41 sec
then 125Vrms, ramp down, tr > 10 sec
then 115Vrms.
135
G 180Vrms, 3 x 20 msec, 0.5 sec apart, tf < 0.5 cyc, tr < 0.5 cyc 54
Under Voltage
H 85Vrms, 180 msec, tf < 0.5 cyc, tr < 0.5 cyc 54
I 85Vrms, 180 msec, tf < 0.5 cyc, tr = 87 ms
then 90Vrms, ramp up, tr = 253 msec
then 95Vrms, ramp up, tr = 6.41 sec
then 100Vrms, ramp up, tr > 10 sec
then 115Vrms.
135
J 66Vrms, 78 msec, tf < 0.5 cyc, tr < 0.5 cyc 54
K 65Vrms, 78 msec, tf < 0.5 cyc, tr = 31 ms
then 75Vrms, ramp up, tr = 71 msec
then 85Vrms, ramp up, tr = 87 msec
then 90Vrms, ramp up, tr = 253 msec
then 95Vrms, ramp up, tr = 6.41 sec
then 100Vrms, ramp up, tr > 10 sec
then 115Vrms.
135
L 45Vrms, 50 msec, tf < 0.5 cyc, tr < 0.5 cyc 52
M 45Vrms, 50 msec, tf < 0.5 cyc, tr = 11 ms
then 55Vrms, ramp up, tr = 17 msec
then 65Vrms, ramp up, tr = 31 msec
then 75Vrms
,
ram
p
u
p,
tr = 71 msec
135
California Instruments 174