User manual
User Manual – Rev B FCS Series II
TAC 302 Tests – Revision A
TAC302 Abnormal Voltage Transients. Rev A
Condition Duration (s)
Over Voltage
A 140Vrms, 1450 msec, tf < 1.25 ms, tr < 1.25 ms 54
B 140Vrms, 1025 msec, tf < 1.25 ms, tr = 850 ms 135
C 160Vrms, 520 msec, tf < 1.25 ms, tr < 1.25 ms 54
D 160Vrms, 390 msec, tf < 1.25 ms, tr = 250 ms 135
E 180Vrms, 98 msec, tf < 1.25 ms, tr < 1.25 ms 54
F 180Vrms, 75 msec, tf < 1.25 ms, tr = 50 ms 135
G 180Vrms, 3 x 20 msec, 0.5 apart, tf < 1.25 ms, tr < 1.25 ms 54
Under Voltage
H 85Vrms, 1450 msec, tf < 1.25 ms, tr < 1.25 ms 54
I 85Vrms, 1025 msec, tf < 1.25 ms, tr = 850 ms 135
J 75Vrms, 520 msec, tf < 1.25 ms, tr < 1.25 ms 54
K 5Vrms, 390 msec, tf < 1.25 ms, tr = 250 ms 7 135
L 45Vrms, 98 msec, tf < 1.25 ms, tr < 1.25 ms 54
M 45Vrms, 75 msec, tf < 1.25 ms, tr = 50 ms 135
N 45Vrms, 3 x 20 msec, 0.5 apart, tf < 1.25 ms, tr < 1.25 ms 54
Combined Transient
O 45Vrms, 20 msec, tf < 1.25 ms, tr < 1.25 ms 135
180Vrms, 75 msec, tf < 1.25 ms, tr = 50 ms
California Instruments 166