User manual
User Manual – Rev B FCS Series II
SAC 301 Tests – Revisions C, E, F
SAC301 Abnormal SS Limits Volt and Freq Rev C, E, F
Condition Duration (s)
Nominal Voltage
A Vnom 115V, Flow 380 Hz 1800
B 1800 Vnom 115V, Fhigh 420 Hz
Low Voltage
C Vlow 100V, Fnom 400 Hz 1800
D Vlow 100V, Flow 380 Hz 1800
E Vlow 100V, Fhigh 420 Hz 1800
High Voltage
F 1800 Vhigh 125V, Fnom 400 Hz
G Vhigh 125V, Flow 380 Hz 1800
H Vhigh 125V, Fhigh 420 Hz 1800
SAC 30 R1 Tests – evisions B, D
SAC301 Abnormal SS Limits Volt and Freq Rev B, D
Condition Duration (s)
Nominal Voltage
A
Vnom 115V, Flow 375 Hz
1800
B
Vnom 115V, Fhigh 425 Hz
1800
Low Voltage
C
Vlow 100V, Fnom 400 Hz
1800
D
Vlow 100V, Flow 375 Hz
1800
E 1800
Vlow 100V, Fhigh 425 Hz
High Voltage
F
Vhigh 125V, Fnom 400 Hz
1800
G
Vhigh 125V, Flow 375 Hz
1800
H
Vhigh 125V, Fhigh 425 Hz
1800
SAC 301 Tests – Revisions A
SAC301 Abnormal SS Limits Volt and Freq Rev A
Condition Duration (s)
Nominal Voltage
A
Vnom 115V, Flow 370 Hz
1800
B
Vnom 115V, Fhigh 430 Hz
1800
Low Voltage
C
Vlow 102V, Fnom 400 Hz
1800
D
Vlow 102V, Flow 370 Hz
1800
E
Vlow 102V, Fhigh 430 Hz
1800
High Voltage
F
Vhigh 124V, Fnom 400 Hz
1800
G
Vhigh 124V, Flow 370 Hz
1800
H
Vhigh 124V, Fhigh 430 Hz
1800
California Instruments 151