User manual
User Manual – Rev B FCS Series II
11.7 Test Steps and Execution Times Summary
With the release of revision F and the accompanying test protocol handbook, the MIL-STD 704
has grown in scope considerably. Rather than duplicating all this information in this user manual,
the user is referred to the MIL-STD 704 Specification documentation for test details on each
specific est.
this section. Approximate test times are
standard revisions, separate tables are shown for
11.7.1 AC Group - Singe phase 400 Hz AC tests
t
A summary of tests arranged by group is provided in
shown for each tests. Where tests differ by
revisions that differ in test levels and or execution times.
S
SAC 102 Tests - Revisions C, D, E, F
SAC102 Steady State Voltage and Frequency - Rev C-F
Condition Duration (s)
Nominal Voltage
A Vnom=115V, Fnom=400 Hz - Nominal 1800
B Vnom=115V, Flow=393 Hz - Nominal 1800
C Vnom=115V, Fhigh=407 Hz - Nominal 1800
Low Voltage
D Vlow =108V, Fnom=400 Hz - Low 1800
E Vlow=108V, Flow= 393 Hz- Low 1800
F Vlow=108V, Fhigh=407 Hz - Low 1800
High Voltage
G Vhigh=118V, Fnom=400 Hz - High 1800
H Vhigh=118V, Flow=393 Hz- High 1800
I Vhigh=118V, Fhigh=407 Hz - High 1800
SAC 102 Tests - Revision B
SAC102 Steady State Voltage and Frequency - Rev B
Condition Duration (s)
Nominal Voltage
A Vnom=115V, Fnom=400 Hz - Nominal 1800
B Vnom=115V, Flow=395 Hz - Nominal 1800
C Vnom=115V, Fhigh=405 Hz - Nominal 1800
Low Voltage
D Vlow =108V, Fnom=400 Hz - Low 1800
E Vlow=108V, Flow= 395 Hz- Low 1800
F Vlow=108V, Fhigh=405 Hz - Low 1800
High Voltage
G Vhigh=118V, Fnom=400 Hz - High 1800
H Vhigh=118V, Flow=395 Hz- High 1800
I Vhigh=118V, Fhigh=405 Hz - High 1800
SAC 102 Tests - Revision A
SAC102 Steady State Voltage and Frequency - Rev A
Condition Duration (s)
Nominal Voltage
A Vnom=115V, Fnom=400 Hz - Nominal 1800
B Vnom=115V, Flow=380 Hz - Nominal 1800
C Vnom=115V, Fhigh=420 Hz - Nominal 1800
Low Voltage
D Vlow =108V, Fnom=400 Hz - Low 1800
E Vlow=108V, Flow= 380 Hz- Low 1800
F Vlow=108V, Fhigh=420 Hz - Low 1800
California Instruments 144