User manual

User Manual – Rev B FCS Series II
Output Parameter Specification
Frequency
Range: 45 Hz - 1200 Hz [Standard, -HV option]
45 Hz – 1000 Hz [-EHV option]
Supplemental Operation from 17 to 45 Hz is available at reduced output voltage.
Vout max = 100 % * F /45 for F < 45Hz. See chart
Figure 2-3 for
Voltage/Frequency rating.
Resolution
1
: 0.01 Hz [< 81.91 Hz]
0.1 Hz [> 82.0 to 819.1 Hz]
1 Hz
2
[> 819 Hz]
Accuracy: ± 0.025 %
Temp. Coefficient ± 5 ppm of value / °C
Stability: ± 15 ppm of value
Phase (3 phase mode)
Range: Phase B/C relative to phase A
0.0 to 360.0°
Resolution: 0.1° < 819.1 Hz
0.5° > 819.1 Hz
Accuracy: < 1° [45 Hz - 1000 Hz]
< 2 [1000 Hz – 1200 Hz]
Distortion (% THD)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
10 100 1000 10000
Output Frequency
Figure 2-1: Distortion as a function of Output Frequency
1
Programming resolution reduced if –LKM/-LKS option is installed. See paragraphs 2.6.3.
2
Programming resolution of 0.5 Hz above 819.1 Hz may be used over the remote control bus with ± 0.5 Hz
accuracy.
California Instruments 14