User manual

User Manual – Rev B FCS Series II
11.4 Power Group Reference
The following power groups are supported by the –704F option.
Test Group Description
704F_TP_SAC Single phase, AC mode, 400 Hz nominal frequency
704F_TP_SVF Single phase, AC mode, variable nominal frequency
704F_TP_SXF Single phase, AC mode, 60 Hz nominal frequency
704F_TP_TAC Three phase, AC mode, 400 Hz nominal frequency
704F_TP_TVF Three phase, AC mode, variable nominal frequency
Table 11-1: DO160 Test Groups
Tests 11.5 Available
Available tests at the Group level are shown in this section. For details on test levels and test
11.5.1 Normal Operation
times for various test conditions in each group, refer to section 11.7 in this manual.
AC Mode:
Test Section
Steady State Limits for Voltage and Frequency (Includes Unbalance) 102
Voltage Phase Difference 103
Voltage Modulation 104
Frequency Modulation 105
Tot e Distal Voltag ortion 107
Normal Voltage Transient 109
Normal Frequency Transient 110
11.5.2 Tran perasfer O tion
AC Mode:
Test Section
Power Interrup 201 t
California Instruments 139